{"id":7179,"date":"2026-01-16T15:40:26","date_gmt":"2026-01-16T14:40:26","guid":{"rendered":"https:\/\/www.hws-mainz.de\/?p=7179"},"modified":"2026-08-23T20:20:45","modified_gmt":"2026-08-23T18:20:45","slug":"precise-temperature-control-glass-reactors","status":"publish","type":"post","link":"https:\/\/www.hws-mainz.de\/fr\/precise-temperature-control-glass-reactors\/","title":{"rendered":"How to Achieve Precise Temperature Control in Laboratory Glass Reactors"},"content":{"rendered":"<p>Precise temperature control means regulating the actual reaction temperature accurately and reproducibly under real laboratory conditions. It depends on system design and control mode, not raw heating power, and thermal boundary conditions can differ as work scales. In a documented Huber\u2013HWS case study, a 5-litre reactor reached a 100&nbsp;\u00b0C process setpoint under process control with a measured ramp rate above 6.6&nbsp;K\/min.<\/p>\n<h2 id=\"What_Is_Precise_Temperature_Control_in_a_Glass_Reactor\"><strong>What Is Precise Temperature Control in a Glass Reactor?<\/strong><\/h2>\n<p><strong>Direct answer:<\/strong><br \/>Precise <a href=\"https:\/\/www.hws-mainz.de\/fr\/electronic-devices\/temperature-controller\/\">temperature control<\/a> means regulating the <strong>actual reaction temperature<\/strong> accurately and reproducibly under real laboratory conditions.<\/p>\n<p>In a documented case study, a <strong>5-litre <a href=\"https:\/\/www.hws-mainz.de\/fr\/products\/custom-laboratory-glassware\/benchtop-flange-glass-reactors\/\">HWS jacketed glass reactor<\/a><\/strong> reached a <strong>100&nbsp;\u00b0C process setpoint in ~12 minutes<\/strong> under process control, with a <strong>measured process ramp rate &gt; 6.6&nbsp;K\/min<\/strong>, demonstrating that modern glass reactor design can support fast, stable thermal control without becoming the limiting factor.<\/p>\n<h2 id=\"How_Does_Temperature_Control_in_Jacketed_Glass_Reactors_Work\"><strong>How Does Temperature Control in Jacketed Glass Reactors Work?<\/strong><\/h2>\n<p><strong>Direct answer:<\/strong><br \/>Temperature control relies on circulating a heat-transfer fluid through the reactor jacket while a control unit adjusts heating or cooling based on the process temperature.<\/p>\n<h3 id=\"Step-by-step_with_case-study_grounding\">Step-by-step (with case-study grounding)<\/h3>\n<ol>\n<li><strong>Heat is applied through the reactor jacket, not directly to the process<\/strong><br \/>In the HWS case study, the jacket temperature was driven to ~135&nbsp;\u00b0C to pull the process smoothly to 100&nbsp;\u00b0C, illustrating controlled thermal decoupling rather than brute-force heating.<\/li>\n<li><strong>Process temperature is used as the control variable<\/strong><br \/>Despite jacket overshoot, the process temperature showed no oscillation, confirming that process-controlled modes suppress instability caused by thermal inertia.<\/li>\n<li><strong>Thermal losses are compensated automatically<\/strong><br \/>The system maintained high ramp rates even with <strong>3&nbsp;m total hose length<\/strong>, a common source of lag in lab installations.<\/li>\n<li><strong>Mixing ensures internal temperature homogeneity<\/strong><br \/>A moderate stirrer speed (200&nbsp;rpm) was sufficient to avoid internal gradients, confirming that excessive agitation is not required when heat transfer is well designed.<\/li>\n<\/ol>\n<h2 id=\"Theory_vs_Demonstrated_Performance\">Theory vs. Demonstrated Performance<\/h2>\n<div style=\"overflow-x:auto;margin:1.5em 0;\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Aspect<\/th>\n<th scope=\"col\">Common Assumption<\/th>\n<th scope=\"col\">Demonstrated in HWS Case Study<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Glass limits ramp rates<\/td>\n<td>Often assumed<\/td>\n<td>Process ramp &gt; 6.6&nbsp;K\/min<\/td>\n<\/tr>\n<tr>\n<td>Jacket overshoot is bad<\/td>\n<td>Seen as a flaw<\/td>\n<td>Enables smooth process control<\/td>\n<\/tr>\n<tr>\n<td>Long hoses ruin control<\/td>\n<td>Feared<\/td>\n<td>Stable control with 2 \u00d7 1.5&nbsp;m hoses<\/td>\n<\/tr>\n<tr>\n<td>High power is required<\/td>\n<td>Overemphasized<\/td>\n<td>Control strategy mattered more<\/td>\n<\/tr>\n<tr>\n<td>Glass reactors are \u201cslow\u201d<\/td>\n<td>Persistent myth<\/td>\n<td>Empirically disproven<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"Why_Control_Strategy_Matters_More_Than_Heating_Power\"><strong>Why Control Strategy Matters More Than Heating Power<\/strong><\/h2>\n<p><strong>Direct answer:<\/strong><br \/>Control strategy has a greater impact on temperature accuracy than nominal heating capacity.<\/p>\n<p>Many users assume higher kilowatt ratings lead to better control. In practice, excess power often causes overshoot and instability. Proper control logic prevents this.<\/p>\n<p>The temperature profiles show how aggressive jacket heating can coexist with smooth process temperature control. The jacket temperature rises quickly, while the process temperature follows a stable path to the setpoint. This behavior highlights the strength of process-controlled operation.<\/p>\n<h3 id=\"Jacket_Control_vs_Process_Control\">Jacket Control vs. Process Control<\/h3>\n<div style=\"overflow-x:auto;margin:1.5em 0;\">\n<table>\n<thead>\n<tr>\n<th scope=\"col\">Aspect<\/th>\n<th scope=\"col\">Jacket Control<\/th>\n<th scope=\"col\">Process Control<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Controlled variable<\/td>\n<td>HTF temperature<\/td>\n<td>Reaction temperature<\/td>\n<\/tr>\n<tr>\n<td>Response to disturbances<\/td>\n<td>Indirect<\/td>\n<td>Direct<\/td>\n<\/tr>\n<tr>\n<td>Risk of overshoot<\/td>\n<td>High<\/td>\n<td>Low<\/td>\n<\/tr>\n<tr>\n<td>Reproducibility<\/td>\n<td>Moderate<\/td>\n<td>High<\/td>\n<\/tr>\n<tr>\n<td>Suitable for exotherms<\/td>\n<td>Limited<\/td>\n<td>Strong<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2 id=\"What_the_Huber%E2%80%93HWS_Case_Study_Teaches_R_D_Labs%E2%80%9D\">What the Huber\u2013HWS Case Study Teaches R&amp;D Labs\u201d<\/h2>\n<p><strong>Direct answer:<\/strong><br \/>The case study shows that temperature control quality in glass reactors depends more on <strong>reactor design and control mode<\/strong> than on nominal heating power.<\/p>\n<h3 id=\"Practical_lessons_for_R_D_and_pilot_labs\">Practical lessons for R&amp;D and pilot labs<\/h3>\n<ul>\n<li>A well-designed glass jacket does not inherently limit heating rates.<\/li>\n<li>Process control allows aggressive jacket temperatures without destabilizing the reaction.<\/li>\n<li>Realistic lab constraints (hoses, partial fill, moderate stirring) can be accommodated without sacrificing precision.<\/li>\n<li>Thermal performance data should be evaluated at the <strong>process level<\/strong>, not the jacket level.<\/li>\n<\/ul>\n<p>This is exactly the type of evidence lab managers need when selecting reactors for development and scale-up work.<\/p>\n<h2 id=\"When_Glass_Reactors_Become_the_Limiting_Factor\"><strong>When Glass Reactors Become the Limiting Factor<\/strong><\/h2>\n<p><strong>Direct answer:<\/strong><br \/>Glass reactors reach their limits during highly viscous reactions, fast heat release, or strong localized exotherms.<\/p>\n<p>Bulk polymerizations and rapid crystallizations can exceed the heat removal capacity of a glass jacket. In such cases, slower ramps, staged heating, or different reactor materials may be required. Recognizing these limits improves experimental design and safety.<\/p>\n<h2 id=\"FAQ_Temperature_Control_in_Laboratory_Glass_Reactors\"><strong>FAQ: Temperature Control in Laboratory Glass Reactors<\/strong><\/h2>\n<h3 id=\"How_fast_can_a_glass_reactor_be_heated\"><strong>How fast can a glass reactor be heated?<\/strong><\/h3>\n<p>Under process control, ramp rates above <strong>6&nbsp;K\/min<\/strong> are achievable in the 5-litre range under realistic lab conditions.<\/p>\n<h3 id=\"Why_does_the_jacket_temperature_exceed_the_process_temperature\"><strong>Why does the jacket temperature exceed the process temperature?<\/strong><\/h3>\n<p>The temperature difference creates the driving force needed for heat transfer. Process control prevents the reaction temperature from overshooting.<\/p>\n<h3 id=\"Do_long_hoses_reduce_control_accuracy\"><strong>Do long hoses reduce control accuracy?<\/strong><\/h3>\n<p>They introduce delay and heat loss. Process control compensates for these effects effectively.<\/p>\n<h3 id=\"Is_higher_stirring_speed_always_better\"><strong>Is higher stirring speed always better?<\/strong><\/h3>\n<p>No. Adequate mixing is enough. Excessive stirring rarely improves temperature control.<\/p>\n<h3 id=\"Can_these_results_guide_pilot-scale_work\"><strong>Can these results guide pilot-scale work?<\/strong><\/h3>\n<p>They provide reliable lab-scale data. Scale-up still requires reassessment of heat transfer and mixing.<\/p>\n<h2 id=\"Conclusion_Precision_Comes_from_Engineering_Not_Assumptions\"><strong>Conclusion: Precision Comes from Engineering, Not Assumptions<\/strong><\/h2>\n<p>Precise temperature control in glass reactors depends on design, control mode, and setup quality. Evidence from laboratory operation shows that modern jacketed glass reactors can deliver fast, stable, and reproducible thermal performance. For R&amp;D and pilot teams, this turns temperature control into a reliable tool rather than an uncertainty.<\/p>","protected":false},"excerpt":{"rendered":"<p>Precise temperature control means regulating the actual reaction temperature accurately and reproducibly under real laboratory conditions. It depends on system design and control mode, not raw heating power, and thermal boundary conditions can differ as work scales. In a documented Huber\u2013HWS case study, a 5-litre reactor reached a 100&nbsp;\u00b0C process setpoint under process control with [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":7182,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[57],"tags":[101],"class_list":["post-7179","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-temperature-control","tag-jacketed-thermal-design"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.4 (Yoast SEO v28.7) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Precise Temperature Control in Glass Reactors Explained - HWS Labortechnik Mainz<\/title>\n<meta name=\"description\" content=\"Learn how to achieve precise temperature control in laboratory glass reactors, with practical engineering insights for R&amp;D and pilot labs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hws-mainz.de\/fr\/precise-temperature-control-glass-reactors\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Achieve Precise Temperature Control in Laboratory Glass Reactors\" \/>\n<meta property=\"og:description\" content=\"Learn how to achieve precise temperature control in laboratory glass reactors, with practical engineering insights for R&amp;D and pilot labs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hws-mainz.de\/fr\/precise-temperature-control-glass-reactors\/\" \/>\n<meta property=\"og:site_name\" content=\"HWS Labortechnik Mainz\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-16T14:40:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-23T18:20:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/01\/Temperature-Control-in-Glass-Reactors-683x1024.png\" \/>\n\t<meta property=\"og:image:width\" content=\"683\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"David Schmidt\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"David Schmidt\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/\"},\"author\":{\"name\":\"David Schmidt\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#\\\/schema\\\/person\\\/8d8683ffb7a9392388ac92796048d38a\"},\"headline\":\"How to Achieve Precise Temperature Control in Laboratory Glass Reactors\",\"datePublished\":\"2026-01-16T14:40:26+00:00\",\"dateModified\":\"2026-08-23T18:20:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/\"},\"wordCount\":849,\"publisher\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hws-mainz.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Temperature-Control-in-Glass-Reactors.png\",\"keywords\":[\"Jacketed &amp; Thermal Design\"],\"articleSection\":[\"Temperature Control\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/\",\"url\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/\",\"name\":\"Precise Temperature Control in Glass Reactors Explained - HWS Labortechnik Mainz\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hws-mainz.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Temperature-Control-in-Glass-Reactors.png\",\"datePublished\":\"2026-01-16T14:40:26+00:00\",\"dateModified\":\"2026-08-23T18:20:45+00:00\",\"description\":\"Learn how to achieve precise temperature control in laboratory glass reactors, with practical engineering insights for R&D and pilot labs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.hws-mainz.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Temperature-Control-in-Glass-Reactors.png\",\"contentUrl\":\"https:\\\/\\\/www.hws-mainz.de\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/Temperature-Control-in-Glass-Reactors.png\",\"width\":1024,\"height\":1536,\"caption\":\"Temperature control unit regulating a laboratory glass reactor\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/precise-temperature-control-glass-reactors\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.hws-mainz.de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Achieve Precise Temperature Control in Laboratory Glass Reactors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#website\",\"url\":\"https:\\\/\\\/www.hws-mainz.de\\\/\",\"name\":\"HWS Labortechnik Mainz\",\"description\":\"HWS Labortechnik - Laboratory components and laboratory systems made of glass, metal and plastic\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.hws-mainz.de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#organization\",\"name\":\"HWS Labortechnik\",\"url\":\"https:\\\/\\\/www.hws-mainz.de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.hws-mainz.de\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/hws_logo_04_Logo-2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.hws-mainz.de\\\/wp-content\\\/uploads\\\/2026\\\/05\\\/hws_logo_04_Logo-2.jpg\",\"width\":508,\"height\":209,\"caption\":\"HWS Labortechnik Mainz\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/hws-labortechnik\\\/\",\"https:\\\/\\\/www.chemie.de\\\/firmen\\\/13203\\\/hws-hans-w-schmidt-gmbh-co-kg.html\"],\"legalName\":\"HWS Hans W. Schmidt GmbH & Co. KG\",\"alternateName\":[\"HWS Labortechnik Mainz\",\"HWS Mainz\",\"HWS-Labortechnik\",\"Hans W. Schmidt GmbH & Co. KG\"],\"email\":\"info@hws-mainz.de\",\"telephone\":\"+49 6131 374560\",\"vatID\":\"DE149024923\",\"identifier\":{\"@type\":\"PropertyValue\",\"propertyID\":\"Handelsregister (Amtsgericht Mainz)\",\"value\":\"HRA 603\"},\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Saarstra\u00dfe 52\",\"postalCode\":\"55122\",\"addressLocality\":\"Mainz\",\"addressRegion\":\"Rheinland-Pfalz\",\"addressCountry\":\"DE\"},\"description\":\"Manufacturer of laboratory glass reactors, filter units and reactor components in borosilicate glass 3.3 for laboratory and pilot plant.\",\"knowsAbout\":[\"Laboratory glass reactors\",\"Jacketed glass reactors\",\"Borosilicate glass 3.3\",\"Filter nutsches\",\"Bottom outlet valves\",\"Miniplants\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/#\\\/schema\\\/person\\\/8d8683ffb7a9392388ac92796048d38a\",\"name\":\"David Schmidt\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/?s=96&d=mm&r=g\",\"caption\":\"David Schmidt\"},\"description\":\"David Schmidt belongs to the third generation of the family behind HWS Labortechnik. A grandson of the founder, he grew up close to the Mainz workshop where HWS has developed and hand-crafted borosilicate glass apparatus since 1941. Through his work with the HWS team, he helps carry the family's eight decades of accumulated experience in laboratory glass technology forward.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/david-schmidt-24b63a357\\\/\"],\"worksFor\":{\"@id\":\"https:\\\/\\\/www.hws-mainz.de\\\/fr\\\/#organization\"},\"url\":\"https:\\\/\\\/www.hws-mainz.de\\\/fr\\\/author\\\/david-schmidt\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Precise Temperature Control in Glass Reactors Explained - HWS Labortechnik Mainz","description":"Learn how to achieve precise temperature control in laboratory glass reactors, with practical engineering insights for R&D and pilot labs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hws-mainz.de\/fr\/precise-temperature-control-glass-reactors\/","og_locale":"fr_FR","og_type":"article","og_title":"How to Achieve Precise Temperature Control in Laboratory Glass Reactors","og_description":"Learn how to achieve precise temperature control in laboratory glass reactors, with practical engineering insights for R&D and pilot labs.","og_url":"https:\/\/www.hws-mainz.de\/fr\/precise-temperature-control-glass-reactors\/","og_site_name":"HWS Labortechnik Mainz","article_published_time":"2026-01-16T14:40:26+00:00","article_modified_time":"2026-08-23T18:20:45+00:00","og_image":[{"width":683,"height":1024,"url":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/01\/Temperature-Control-in-Glass-Reactors-683x1024.png","type":"image\/png"}],"author":"David Schmidt","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"David Schmidt","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#article","isPartOf":{"@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/"},"author":{"name":"David Schmidt","@id":"https:\/\/www.hws-mainz.de\/#\/schema\/person\/8d8683ffb7a9392388ac92796048d38a"},"headline":"How to Achieve Precise Temperature Control in Laboratory Glass Reactors","datePublished":"2026-01-16T14:40:26+00:00","dateModified":"2026-08-23T18:20:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/"},"wordCount":849,"publisher":{"@id":"https:\/\/www.hws-mainz.de\/#organization"},"image":{"@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/01\/Temperature-Control-in-Glass-Reactors.png","keywords":["Jacketed &amp; Thermal Design"],"articleSection":["Temperature Control"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/","url":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/","name":"Precise Temperature Control in Glass Reactors Explained - HWS Labortechnik Mainz","isPartOf":{"@id":"https:\/\/www.hws-mainz.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#primaryimage"},"image":{"@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/01\/Temperature-Control-in-Glass-Reactors.png","datePublished":"2026-01-16T14:40:26+00:00","dateModified":"2026-08-23T18:20:45+00:00","description":"Learn how to achieve precise temperature control in laboratory glass reactors, with practical engineering insights for R&D and pilot labs.","breadcrumb":{"@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#primaryimage","url":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/01\/Temperature-Control-in-Glass-Reactors.png","contentUrl":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/01\/Temperature-Control-in-Glass-Reactors.png","width":1024,"height":1536,"caption":"Temperature control unit regulating a laboratory glass reactor"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hws-mainz.de\/precise-temperature-control-glass-reactors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hws-mainz.de\/"},{"@type":"ListItem","position":2,"name":"How to Achieve Precise Temperature Control in Laboratory Glass Reactors"}]},{"@type":"WebSite","@id":"https:\/\/www.hws-mainz.de\/#website","url":"https:\/\/www.hws-mainz.de\/","name":"HWS Labortechnik Mainz","description":"HWS Labortechnik - Laboratory components and laboratory systems made of glass, metal and plastic","publisher":{"@id":"https:\/\/www.hws-mainz.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hws-mainz.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.hws-mainz.de\/#organization","name":"HWS Labortechnik","url":"https:\/\/www.hws-mainz.de\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.hws-mainz.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/05\/hws_logo_04_Logo-2.jpg","contentUrl":"https:\/\/www.hws-mainz.de\/wp-content\/uploads\/2026\/05\/hws_logo_04_Logo-2.jpg","width":508,"height":209,"caption":"HWS Labortechnik Mainz"},"image":{"@id":"https:\/\/www.hws-mainz.de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/hws-labortechnik\/","https:\/\/www.chemie.de\/firmen\/13203\/hws-hans-w-schmidt-gmbh-co-kg.html"],"legalName":"HWS Hans W. Schmidt GmbH & Co. KG","alternateName":["HWS Labortechnik Mainz","HWS Mainz","HWS-Labortechnik","Hans W. Schmidt GmbH & Co. KG"],"email":"info@hws-mainz.de","telephone":"+49 6131 374560","vatID":"DE149024923","identifier":{"@type":"PropertyValue","propertyID":"Handelsregister (Amtsgericht Mainz)","value":"HRA 603"},"address":{"@type":"PostalAddress","streetAddress":"Saarstra\u00dfe 52","postalCode":"55122","addressLocality":"Mainz","addressRegion":"Rheinland-Pfalz","addressCountry":"DE"},"description":"Manufacturer of laboratory glass reactors, filter units and reactor components in borosilicate glass 3.3 for laboratory and pilot plant.","knowsAbout":["Laboratory glass reactors","Jacketed glass reactors","Borosilicate glass 3.3","Filter nutsches","Bottom outlet valves","Miniplants"]},{"@type":"Person","@id":"https:\/\/www.hws-mainz.de\/#\/schema\/person\/8d8683ffb7a9392388ac92796048d38a","name":"David Schmidt","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","caption":"David Schmidt"},"description":"David Schmidt belongs to the third generation of the family behind HWS Labortechnik. A grandson of the founder, he grew up close to the Mainz workshop where HWS has developed and hand-crafted borosilicate glass apparatus since 1941. Through his work with the HWS team, he helps carry the family's eight decades of accumulated experience in laboratory glass technology forward.","sameAs":["https:\/\/www.linkedin.com\/in\/david-schmidt-24b63a357\/"],"worksFor":{"@id":"https:\/\/www.hws-mainz.de\/fr\/#organization"},"url":"https:\/\/www.hws-mainz.de\/fr\/author\/david-schmidt\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/posts\/7179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/comments?post=7179"}],"version-history":[{"count":18,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/posts\/7179\/revisions"}],"predecessor-version":[{"id":7665,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/posts\/7179\/revisions\/7665"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/media\/7182"}],"wp:attachment":[{"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/media?parent=7179"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/categories?post=7179"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hws-mainz.de\/fr\/wp-json\/wp\/v2\/tags?post=7179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}